Precautions for high frequency induction heating power supply
Latest company news about Precautions for high frequency induction heating power supply

1. Please read the instruction manual carefully before installation.


2. Pay attention to the electrical installation of the equipment: This equipment is a high-power equipment, the equipment connection must be firm, and the electrical connection should be reduced to 79483MD as much as possible. Do not simply hang the power cord on the power grid.
 

3. When connecting to a single-phase 220V power supply, one is connected to the live wire and the other is connected to the neutral wire. It is absolutely not allowed to add a ground wire in place of the neutral wire; the three-phase connection is 380V.
 

4. Precautions for installation of induction coil:
(1) When the diameter of the 15kw 25kw series induction coil is less than 100mm, the single-turn induction coil cannot be used, otherwise it will damage the equipment whose operating frequency is too high;
(2) When installing the induction coil, never use materials such as waterproof tape, because the induction coil is both water and electricity. If the induction coil is used, it will cause poor electrical contact, make the machine unable to start or cause other problems; if there is water leakage at the connection of the induction coil, the copper bell mouth at the connection of the induction coil can be annealed and softened to improve the sealing condition;
(3) For customers who need to replace the induction coil frequently during work, in order to avoid the connection screw of the induction coil on the equipment from slipping, it is recommended to use an "induction coil intermediate adapter", that is, install an adapter on the equipment, and install the induction coil on the adapter. On the other hand, due to the slippage of the induction coil connecting screw, the maintenance rate of the equipment can be reduced.

 

5. Ordinary equipment under 15kw has no water pressure protection function. The water supply situation should be confirmed before starting the machine, otherwise the equipment may be burnt out, causing unnecessary losses and troubles to you.
 

6. Note on the installation of the split cable: When installing the split cable quick connector, the buckle must be rotated to achieve a good connection; due to the frequent swinging of the cable during use, the quick connector is easy to loosen, resulting in poor contact and cause failure.